Bleeding the ACE system

K-rover

Well-known member
Jan 15, 2010
2,179
69
Raleigh, NC
I have to replace the actuator. According to the RAVE file, I have to hook it up to the Testbook in order to bleed the system. Is that the only way?
 

Roustabout

Active member
Mar 27, 2010
28
0
Ontario, Canada
I had to replace an actuator and unfortunately the only way to properly bleed the actuator side of the system is to have the actuator fully extended with the pump running. I used the Hawkeye to bleed mine -firmware version 4 and above has the bleed routine.